Mic ETS2228 Instrukcja Użytkownika Strona 14

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 13
ETS2228 Maintenance Manual
All right reserved Page 14, Total 43
Input power level conversion circuit:
Figure 2 Input power level conversion circuit
Output power level conversion circuit:
Figure 3 Output power level conversion circuit
Data receiving signal power level conversion circuit. The power level conversion of signal
UART1_RX is accomplished by clamp circuit. The reason lies in that the signal power-level needs to be
lowered to detect whether or not the serial port line is connected when there are no data lines.
Przeglądanie stron 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 42 43

Komentarze do niniejszej Instrukcji

Brak uwag